Among these, the large majority consisted of amplicons that were present only in specific stages of development of the apomictic flowers. Ten percent of polymorphic amplicons were present with almost identical intensity in all stages of the apomictic flowers and never in the sexual flowers. Reverse transcription-PCR (RT-PCR) and Southern analyses of these amplicons showed that they belong to constitutively expressed
alleles that are specifically present on the apomixis-controlling locus of P. simplex. The most frequent biological functions inferred from the sequence homology of the apomixis-linked alleles were related to signal transduction and nucleic acid/protein-binding activities. Most of these apomixis-linked alleles showed nonsense and frameshift mutations, revealing their probable pseudogene nature. None of the amplicons that were present only in specific stages of development of the apomictic flowers co-segregated with apomixis, indicating they click here did not originate from additional apomictic alleles but more
probably from differential regulation of the same allele in apomictic and sexual flowers. The molecular functions inferred from sequence analysis of these latter amplicons were related to seed storage protein and regulatory genes of various types. The results are discussed regarding the possible role in apomictic reproduction of the differentially expressed genes in relation to their specificity of expression and inferred molecular functions.”
“Purpose Selleck Quisinostat of the study: Optimal hand position for chest compressions
during cardiopulmonary resuscitation is unknown. Recent imaging studies indicate significant inter-individual anatomical variations, which might cause varying haemodynamic responses with standard chest compressions. This prospective clinical pilot study intended to assess the feasibility of utilizing capnography to optimize chest compressions and identify the optimal hand position.\n\nMaterials and methods: Intubated cardiac arrest patients treated by the physician manned ambulance between February and December 2011 monitored with continuous Selleckchem AZD1208 end-tidal CO2 (EtCO2) measurements were included. One minute of chest compressions at the inter-nipple line (INL) optimized using EtCO2 feedback, was followed by four 30-s intervals with compressions at four different sites; INL, 2 cm below the INL, 2 cm below and to the left of INL and 2 cm below and to the right of INL.\n\nResults: Thirty patients were included. At the end of each 30-s interval median (range) EtCO2 was 3.1 kPa (0.7-8.7 kPa) at INL, 3.5 kPa (0.5-10.7) 2 cm below INL, 3.5 kPa (0.5-10.3 kPa) 2 cm below and to the left of INL, and 3.8 kPa (0.4-8.8 kPa) 2 cm below and to the right of INL (p = 0.4). The EtCO2 difference within each subject between hand positions with maximum and minimum values varied between individuals from 0.2 to 3.4 kPa (median 0.9 kPa).\n\nConclusion: Monitoring and optimizing chest compressions using capnography was feasible.