2003) Each volume consisted of 33 axial slices (64 × 64 matrix,

2003). Each volume consisted of 33 axial slices (64 × 64 matrix, 3.75 × 3.75 mm2, 3.5 mm thickness, 1 mm gap). In addition, a high-resolution T1-weighted 3D MP-RAGE anatomical image was acquired (TR = 2530 msec, TE = 1.64 msec, flip angle = 7°, 192 sagittal slices, 256 × 256 matrix, slice thickness = 1 mm) for each participant. DTI scans were acquired via single-shot, spin-echo, echo-planar imaging (EPI) with a twice-refocused balanced echo sequence to reduce eddy current

distortions. DTI data were collected along the AC/PC line, with FOV = 256 × 256 mm, 128 × 128 matrix, slice thickness Inhibitors,research,lifescience,medical of 2 mm (isotropic 2 mm resolution), NEX = 1, TE = 84 msec, and TR = 9000 msec. Inhibitors,research,lifescience,medical A multiple-channel radiofrequency (RF)

coil was used, with GRAPPA (X2), 30 gradient directions, and b = 800 sec/mm2, and the b = 0 experiment was repeated five times (Jones et al. 1999). See Figure 1 for a schematic of data processing and analysis steps following image acquisition. Figure 1 Schematic of data processing and analysis steps. DTI analysis DTI preprocessing entailed (1) data quality check, (2) motion eddy current correction, and (3) adjustment of diffusion gradient directions. Data quality check Inhibitors,research,lifescience,medical The DTI data were checked for: (1) signal dropout due to subject motion, producing striated artifacts on images; (2) excessive background noise in the phase encoding direction, due to external RF leakage in the MRI scan room or subject motion; and (3) large amounts of motion in the absence of signal dropout. A DTI volume was dropped if the motion was more than 4 mm Inhibitors,research,lifescience,medical of

root mean square displacement. If more than 10% of gradient directions were dropped for any of the above reasons, then the subject was not considered for further analysis. Of 481 participants scanned, data for 145 were excluded by stringent quality control, leaving 336 participants Inhibitors,research,lifescience,medical with acceptable DTI data. Exclusions were typically due to Staurosporine research buy participant motion or scanner noise. The data quality check considered the effects of motion in two ways. If the participant moved during acquisition of a specific Bay 11-7085 brain volume, then the image quality was degraded. After the participant ceased movement and held still at a new location, the image quality would be good, but the motion registration algorithm would show a large displacement. The combined quality check criterion was highly stringent, as evidenced by its exclusion of 30% of participants who were scanned. The criterion of excluding the participant from further DTI analysis if 10% of the gradient directions were dropped was based on empirical findings from a previous study by our group (Ling et al. 2012). Motion and eddy current correction We registered all the images to a b = 0 sec/mm2 image.

Leave a Reply

Your email address will not be published. Required fields are marked *

*

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>